• VMIVME-3113A   12-bit AD converter  Supports live and offline built-in testing
  • VMIVME-3113A   12-bit AD converter  Supports live and offline built-in testing

VMIVME-3113A 12-bit AD converter Supports live and offline built-in testing

No.VMIVME-3113A
The GE Fanuc/VMIVME-3113A is designed to support 64-channel differential or single-ended wide-range (+/-10mV to +/-10V) analog inputs. 64-word dual ports provide storage for continuous scanning of all channels. Scan mode is performed automatically on power-on, system reset, or under program control. A dual-port register allows access to the VMEbus at any time to read the latest stored data. Jumper Optional programmable gain amplifiers support gain ranges of 1, 10, 100, 200 and 500. The A/D conversion time is 15μs. Supports a variety of low-pass filters.
  • VMIVME-3113A   12-bit AD converter  Supports live and offline built-in testing
Desciption
Features:
64 differential or single-ended inputs
Optional scanning of jumpers from 2 to 64 channels
Five operating modes and test modes
8-bit continuous digitizing for dedicated channel dual-port registers

• 64 differential or single-ended inputs
• Powers up in autoscanning mode — no software initialization required
• Continually digitizes input channels and stores the results in a dedicated 
channel dual-port register (autoscanning mode)
• Jumper-selectable scanning of 2 to 64 channels
• Supports real-time and off-line Built-in-Test
• Five operating modes plus test mode
— Autoscanning mode (gain=1)
— Random poll mode
— Random interrupt mode
— Scanning poll mode
— Scanning interrupt mode
• VMEbus interrupts may be programmed to interrupt upon completion of a 
single A/D conversion or upon completion of a 2- through 64-channel scan
• User-programmable interval timer supports scanning of all channels at 
periodic intervals
• Jumper-programmable gain 1, 10, 100, 200, and 500
• Selectable A/D ranges of 0 to +10 V, ±5 V, and ±10 V


• Low-level and high-level inputs: ±10 mV to ±10 V
• Optional low pass filter (the VMIVME-3113A has improved high-frequency 
rejection characteristics)
• Overvoltage protected inputs
• 5 x 106 Ω input impedance
• 33 kHz conversion rate
• Selectable output code: binary, offset binary, two’s complement with sign 
extension
APPLICATIONS
• Factory automation and instrumentation
• Process control
• Laboratory instrumentation
• Machine monitoring
• Data acquisition
Contact
NEED HELP TO PROVIDE THE BEST AFTER-SALES SERVICE
Contact information

E-mail: [email protected]

Customer service QQ: 2082431634

Mobile: 18059868280 (wechat official account)

 
CONTACT US