MTL 8715-CA-BI is an analog signal isolation grid designed to isolate and transmit analog signals from 4-20mA
Basic parameters of MTL 8715-CA-BI:
Input signal: 4-20mA DC
Output signal: 4-20mA DC or 1-5V DC
Isolation voltage: 1500V AC
Frequency response range: DC-10kHz
Linearity error: +0.1%.
Power supply voltage: 18-32V DC
Operating temperature range: -20°C to +60°C
Mounting method: 35mm DIN rail mounting
Dimensions: 22.5mm x 99mm x 114mm
Amount: About 160g
  • 8715-CA-BI MTL Bus interface module
  • 8715-CA-BI MTL Bus interface module
  • 8715-CA-BI MTL Bus interface module

Desciption

MTL 8715-CA-BI is an analog signal isolation grid designed to isolate and transmit analog signals from 4-20mA
Basic parameters of MTL 8715-CA-BI:
Input signal: 4-20mA DC
Output signal: 4-20mA DC or 1-5V DC
Isolation voltage: 1500V AC
Frequency response range: DC-10kHz
Linearity error: +0.1%.
Power supply voltage: 18-32V DC
Operating temperature range: -20°C to +60°C
Mounting method: 35mm DIN rail mounting
Dimensions: 22.5mm x 99mm x 114mm
Amount: About 160g
MTL8715-CA-BI is an analog signal isolation gate, mainly used to isolate and transmit 4-20mA analog signals MTL8715-CA-BI basic parameters:
Input signal :4-20mA DC
Output signal: 4-20mA DC or 1-5V DC Isolation voltage :1500V AC
Frequency response range: DC-10kHz Linearity error: +0.1%
Power supply voltage :18-32V DC
Operating temperature range: -20 °C to + 60°C Mounting method: 35mm DIN rail Mounting Dimension :22.5mm X 99mm X 114mm Weight: about 160g
Functions and actual operation of MTL 8715-CA-BI:
Signal isolation :MTL8715-CA-BI can isolate the input signal, prevent interference between the input loop and the output loop, and ensure the quality of the transmitted signal.
Signal conversion :MTL8715-CA-BI can convert 4-20mA analog signals into corresponding voltage signals, which is convenient for receiving and processing of various instruments, sensors and other equipment. Signal amplification: The MTL8715-CA-BI can amplify the amplitude of the input signal so that the signal can be adapted for longer distance transmission.
Signal protection: The MTL8715-CA-BI has an isolation and protection circuit between the input and output, which can protect the output device from overvoltage, overcurrent and other factors in the input circuit. Improve system reliability
Performance: MTL8715-CA-BII for signal isolation and protection
It can improve the reliability of the system, reduce the system failure rate, and extend the service life of the equipment.
MTL 8715-CA-BI bus interface module Base Heat exchange The CI854A supports heat exchange. It can be replaced online without causing any interference to other units connected to the CEX bus. After hot removal and subsequent insertion, the unit is automatically configured. In redundant configuration
The backup unit can be replaced without interfering with the primary unit. This includes being able to replace the device online if it fails. To support heat exchange, no configuration is required. Hot Configuration in Operation (HCIR) During hot configuration in operation, slave devices can be configured online without initializing the PROFIBUS hot switching. The CI854A supports hot switching. It can be replaced online without causing any disturbance to other units connected to the CEX bus. After hot removal and subsequent insertion, the unit is automatically configured. In a redundant configuration, backup units can be replaced without disturbing the primary unit. This includes an online replacement if the device fails. In order to support heat exchange, no configuration is required.
Contact