The ABB 1MRK002133-ABr02 is a compact numerical overcurrent protection relay designed for low-voltage power distribution systems—think switchgear, panelboards, and motor control centers. It’s built to detect overloads, short circuits, and earth faults, then trip connected circuit breakers to prevent equipment damage or fire. Personally, I’ve installed this relay in a downtown office building’s electrical room, and what stands out is its “plug-and-play” vibe; unlike older electromechanical relays that needed tedious dial adjustments, this one uses a simple push-button interface to set trip thresholds. ABB 1MRK002133-ABr02 also talks to building management systems via Modbus, which let the facility team monitor circuit health remotely—no more walking to the basement just to check if a relay is active. It’s the kind of upgrade that makes electricians and facility managers equally happy: reliable protection without the hassle.
L’ABB 1MRK002133-ABr02 est un relais numérique de protection contre les surintensités compact, conçu pour les systèmes de distribution d’énergie basse tension — comme les armoires de distribution, les panneaux de commande et les centres de contrôle de moteurs. Il est conçu pour détecter les surcharges, les courts-circuits et les défauts de terre, puis déclencher les disjoncteurs connectés pour éviter les dommages aux équipements ou les incendies. Personnellement, j’ai installé ce relais dans la salle électrique d’un immeuble de bureaux au centre-ville, et ce qui se distingue, c’est son côté “brancher et utiliser” ; contrairement aux anciens relais électromécaniques qui nécessitaient des réglages fastidieux à cadran, celui-ci utilise une interface à boutons poussoirs simple pour régler les seuils de déclenchement. Il communique également avec les systèmes de gestion de bâtiment via Modbus, ce qui permet à l’équipe de maintenance de surveiller la santé des circuits à distance — plus besoin d’aller au sous-sol juste pour vérifier si un relais est actif. C’est le genre de mise à niveau qui rend heureux à la fois les électriciens et les gestionnaires de bâtiments : une protection fiable sans tracas.
| Parameter | Value |
|---|---|
| Product Model | ABB 1MRK002133-ABr02 |
| Manufacturer | ABB |
| Product Type | Numerical Overcurrent/Earth Fault Protection Relay |
| Power | 85-264V AC / 24-72V DC (Dual Supply) |
| Communication / Protocol | Modbus RTU (RS485) |
| Operating Temperature | -25°C to +70°C (-13°F to +158°F) |
| Mounting | 35mm Standard DIN Rail |
| Dimensions (HxWxD) | 90mm x 45mm x 120mm (3.5” x 1.8” x 4.7”) |
| Weight | 0.3kg (0.66 lbs) |
| Typical Interfaces | 4 Current Inputs (CT Secondary: 5A), 2 Digital Outputs (Relay), 1 RS485 Port |
| Compliance | CE, UL 508, IEC 60255-1, RoHS |
What I really like is that it doesn’t overcomplicate protection. A lot of “smart” relays have 50+ settings you’ll never use, but ABB 1MRK002133-ABr02 sticks to what matters: fast, accurate tripping and easy setup. For most low-voltage systems, that’s all you need.
Ce que j’aime vraiment, c’est qu’il ne complique pas la protection. Beaucoup de relais “intelligents” ont plus de 50 paramètres que vous n’utiliserez jamais, mais l’ABB 1MRK002133-ABr02 se concentre sur l’essentiel : un déclenchement rapide et précis, et une configuration facile. Pour la plupart des systèmes basse tension, c’est tout ce dont vous avez besoin.
The 1MRK002133-ABr02 is my go-to for standard commercial/industrial circuits (50-200A). The Br01 works for small loads like office lighting, but the Br02 hits the sweet spot for most panelboards and motor controls. No need to overpay for features you don’t need.
Installation takes 10 minutes max: Snap it onto the DIN rail, connect the power (AC or DC—labeled clearly on the terminals), wire the current transformers (CTs) to the input terminals, and link the output relay to the circuit breaker. The wiring diagram is printed on the relay’s side—no need to dig through a manual. Pro tip: Use ferrules on the CT wires; it prevents loose connections.
Maintenance is minimal: Press the “Test” button once a month to verify it triggers the breaker (takes 2 seconds). Once a year, check the wiring tightness—vibration can loosen terminals over time. I’ve had these running for 4 years without a single issue. Unlike old relays that need calibration every 6 months, this one stays accurate for years. It’s the definition of “set it and forget it.”
L’installation prend au maximum 10 minutes : Encliquez-le sur le rail DIN, connectez l’alimentation (AC ou DC — clairement étiqueté sur les bornes), câblez les transformateurs de courant (TC) aux bornes d’entrée, et reliez le relais de sortie au disjoncteur. Le schéma de câblage est imprimé sur le côté du relais — pas besoin de chercher dans un manuel. Astuce : Utilisez des ferrules sur les fils des TC ; cela évite les connexions desserrées.
La maintenance est minimale : Appuyez sur le bouton “Test” une fois par mois pour vérifier qu’il déclenche le disjoncteur (prend 2 secondes). Une fois par an, vérifiez la serrure des fils — les vibrations peuvent desserrer les bornes avec le temps. J’ai eu ces relais en marche pendant 4 ans sans le moindre problème. Contrairement aux anciens relais qui nécessitent un étalonnage tous les 6 mois, celui-ci reste précis pendant des années. C’est la définition de “configurer et oublier”.
ABB offers a 2-year standard warranty for the 1MRK002133-ABr02, covering manufacturing defects (like faulty buttons or communication ports) but excluding damage from incorrect wiring or overvoltage. I’ve filed one claim: a relay arrived with a non-functional RS485 port, and ABB shipped a replacement in 2 days—no forms, no hassle. That’s faster than any other supplier I’ve worked with.
For critical sites (like hospitals or data centers), ABB has a 3-year extended warranty. It costs about 20% more, but it includes priority tech support—ABB’s team calls back within an hour if you hit a problem. Personally, I recommend it for these sites; downtime in a hospital’s electrical system is too risky to skip. Just keep your purchase receipt—ABB asks for it, but the process is smooth.
ABB propose une garantie standard de 2 ans pour l’1MRK002133-ABr02, couvrant les défauts de fabrication (comme des boutons défectueux ou des ports de communication défectueux) mais excluant les dommages dus à un câblage incorrect ou une surtension. J’ai déposé une déclaration : un relais est arrivé avec un port RS485 non fonctionnel, et ABB a expédié un remplacement en 2 jours — pas de formulaires, pas de tracas. C’est plus rapide que tout autre fournisseur avec lequel j’ai travaillé.
Pour les sites critiques (comme les hôpitaux ou les centres de données), ABB propose une garantie étendue de 3 ans. Elle coûte environ 20% de plus, mais elle inclut un support technique prioritaire — l’équipe d’ABB rappelle en moins d’une heure si vous rencontrez un problème. Personnellement, je la recommande pour ces sites ; un arrêt dans le système électrique d’un hôpital est trop risqué pour être ignoré. Il suffit de conserver votre reçu d’achat — ABB le demande, mais le processus est simple.