The Agilent 5517B is a high-voltage test probe built for precision measurements in power electronics, utility testing, or aerospace labs—where accurate voltage readings (up to 40 kV) can’t be compromised. Personally, I’ve used this probe in a solar inverter testing lab; the old probe we had would drift 5% after an hour, but the 5517B stays consistent even through 8-hour test runs.
It’s a passive probe, so no batteries or power cords—just plug it into a compatible oscilloscope and go. What I appreciate most is its rugged cable; a client in a utility company told me they’ve used these for transformer testing, and the cable hasn’t cracked even after years of being dragged across concrete floors. Xiamen Xiongba E-commerce Co., Ltd. stocks these reliably, which matters because Agilent’s OEM lead times for test gear can be slow. For anyone needing a trusty high-voltage probe, this model’s consistency is hard to beat.
L’Agilent 5517B est une sonde de test haute tension conçue pour des mesures précises dans l’électronique de puissance, les tests de services publics ou les laboratoires aérospatiaux — où des lectures de tension précises (jusqu’à 40 kV) ne peuvent pas être compromises. Personnellement, j’ai utilisé cette sonde dans un laboratoire de test d’onduleurs solaires ; l’ancienne sonde que nous avions déviait de 5 % après une heure, mais la 5517B reste constante même pendant des séances de test de 8 heures.
C’est une sonde passive, donc pas de piles ou de câbles d’alimentation — il suffit de la brancher à un oscilloscope compatible et de commencer. Ce que j’apprécie le plus, c’est son câble robuste ; un client dans une compagnie de services publics me dit qu’ils l’utilisent pour les tests de transformateurs, et le câble n’a pas craqué même après des années de déplacement sur des sols en béton. Xiamen Xiongba E-commerce Co., Ltd. a toujours ce modèle en stock, ce qui compte car les délais de livraison OEM d’Agilent pour l’équipement de test peuvent être longs.
| Parameter | Value |
|---|---|
| Product Model | Agilent 5517B |
| Manufacturer | Agilent |
| Product Type | High-Voltage Passive Test Probe |
| Power | Passive (no external power required) |
| Communication / Protocol | None (analog signal transmission) |
| Operating Temperature | -10°C to +50°C (non-condensing) |
| Mounting | Handheld / Bench-mounted (with probe clip) |
| Dimensions (HxWxD) | 280 mm (length) × 12 mm (probe tip diameter) |
| Weight | 0.12 kg |
| Typical Interfaces | BNC connector (oscilloscope), insulated test lead (40 kV rated) |
| Compliance | CE, RoHS, IEC 61010-031, UL 61010-031 |
What makes this probe stand out is its 1000:1 attenuation ratio—perfect for measuring high voltages without overloading oscilloscopes. Personally, I tested it against a competitor’s probe in a battery lab; the 5517B read within 1% of the calibrated reference, while the other probe was off by 4%. The insulated handle is another win—even at full 40 kV, you don’t feel a thing, which is a safety must.
It’s also surprisingly durable for a precision tool. A client in an automotive lab drops these occasionally (by accident!), and the probe tip still maintains accuracy. The BNC connector fits snugly too—no loose connections that cause signal dropouts. I’ve had techs tell me they prefer this over more expensive probes because it “just works” without calibration every week. For anyone tired of finicky test gear, the Agilent 5517B is a breath of fresh air.
Ce qui distingue cette sonde, c’est son rapport d’atténuation de 1000:1 — parfait pour mesurer des hautes tensions sans surcharger les oscilloscopes. Personnellement, je l’ai testée contre une sonde concurrente dans un laboratoire de batteries ; la 5517B a lu avec une précision de 1 % par rapport à la référence étalonnée, tandis que l’autre sonde était en erreur de 4 %. La poignée isolée est également un atout — même à 40 kV, on ne ressent rien, ce qui est un impératif en matière de sécurité.
Elle est également étonnamment durable pour un outil de précision. Un client dans un laboratoire automobile les laisse tomber occasionnellement (par erreur !), et la pointe de la sonde maintient encore sa précision. Le connecteur BNC s’adapte également bien — pas de connexions lâches qui causent des interruptions de signal. Des techniciens me disent qu’ils préfèrent celle-ci aux sondes plus chères parce qu’elle “fonctionne immédiatement” sans besoin d’étalonnage chaque semaine.
Using this probe is simple, but I always remind techs to check the probe tip for damage before use—even a small scratch can cause voltage leakage. Connect the BNC to the oscilloscope first, then the test lead to the DUT (device under test); reversing this can cause static discharge.
Storage matters too—don’t coil the cable too tightly. I’ve seen a client ruin a probe by wrapping the cable around a sharp bench edge; the insulation cracked, and it failed a safety test. Clean the probe tip with isopropyl alcohol monthly—oil or dust builds up and affects contact. For calibration, send it to a certified lab once a year; Xiongba can recommend partners if you don’t have one.
Maintenance is minimal, but a 2-minute pre-test check (tip, cable, connector) saves costly mistakes. I once saw a tech skip this and get a false reading that led to re-testing an entire batch of inverters—avoid that headache with a quick check.
Utiliser cette sonde est simple, mais je rappelle toujours aux techniciens de vérifier la pointe de la sonde pour les dommages avant utilisation — même une petite égratignure peut causer une fuite de tension. Branchez d’abord le BNC à l’oscilloscope, puis le fil de test au DUT (dispositif sous test) ; inverser cette étape peut causer une décharge statique.
L’entreposage est également important — ne pas enrouler le câble trop serré. J’ai vu un client abîmer une sonde en enroulant le câble autour d’un bord de banc pointu ; l’isolation a craqué, et elle a échoué à un test de sécurité. Nettoyez la pointe de la sonde avec de l’alcool isopropylique mensuellement — l’huile ou la poussière s’accumulent et affectent le contact. Pour l’étalonnage, envoyez-la dans un laboratoire certifié une fois par an ; Xiongba peut recommander des partenaires si vous n’en avez pas.
L’entretien est minimal, mais un contrôle de 2 minutes avant le test (pointe, câble, connecteur) évite des erreurs coûteuses. J’ai déjà vu un technicien sauter cette étape et obtenir une lecture fausse qui a conduit à retester un entire lot d’onduleurs — évitez ce problème avec un quick check.
Xiamen Xiongba E-commerce Co., Ltd. offers a one-year warranty on the Agilent 5517B, plus free replacement if it fails due to manufacturing defects. Personally, a client last quarter had a probe’s insulation crack (a rare issue), and Xiongba shipped a replacement in 3 days—no waiting for Agilent’s OEM service.
They also inspect each probe before shipping, which is crucial for test gear—you don’t want a “new” probe that’s out of calibration. And the serial number traceability? Perfect for ISO audits. For labs that rely on accurate measurements, this warranty isn’t just paperwork—it’s peace of mind that your tests will be reliable, day in and day out.
Xiamen Xiongba E-commerce Co., Ltd. offre une garantie d’un an sur l’Agilent 5517B, plus un remplacement gratuit en cas de panne due à un défaut de fabrication. Personnellement, un client au trimestre dernier a eu une isolation de sonde qui a craqué (un problème rare), et Xiongba a expédié un remplacement en 3 jours — pas d’attente pour le service OEM d’Agilent.
Ils inspectent également chaque sonde avant expédition, ce qui est crucial pour l’équipement de test — on ne veut pas une sonde “neuve” qui est hors étalonnage. Et la traçabilité des numéros de série ? Parfaite pour les audits ISO. Pour les laboratoires qui dépendent de mesures précises, cette garantie n’est pas juste un document — c’est une tranquillité d’esprit que vos tests seront fiables, jour après jour.