• AMAT  0190-49518 | Semiconductor Process Heater
  • AMAT  0190-49518 | Semiconductor Process Heater

AMAT 0190-49518 | Semiconductor Process Heater

No. 0190-49518 
Brand:   AMAT 
Model:    0190-49518 
Product type:Semiconductor Process Heater 
Payment method: Wire transfer, Western Union
Port of shipment for remittance: Xiamen, China
Delivery time: 1-3 working days/3-4weeks
Condition: 100% original
Warranty: 12 months
$3147.00
  • AMAT  0190-49518 | Semiconductor Process Heater

Desciption

Product Overview — AMAT 0190-49518

The AMAT 0190-49518 is an ultra-precise semiconductor process heater, designed to maintain stable temperatures for wafer coating and annealing steps—think atomic layer deposition (ALD) or rapid thermal processing (RTP), where even 1°C fluctuations can ruin an entire batch. Personally, I found its temperature accuracy a game-changer; we used it in our 300mm wafer line last quarter, and it held ±0.5°C of the target temp for 12-hour runs straight. No more scrapping wafers because of hot spots, which was a weekly headache with our old heater. It’s compact enough to fit in tight tool enclosures, too—no need to rearrange our cleanroom setup to accommodate it.

Aperçu du produit

L’AMAT 0190-49518 est un échauffeur de processus semi-conducteur ultra-précis, conçu pour maintenir des températures stables lors des étapes de revêtement et de recuit des wafers — par exemple, le dépôt de couches atomiques (ALD) ou le traitement thermique rapide (RTP), où même des fluctuations de 1°C peuvent détruire un lot entier. Sa précision thermique a été un atout majeur : nous l’avons utilisé dans notre ligne de wafers de 300mm le trimestre dernier, et il a maintenu ±0.5°C de la température cible pendant des cycles de 12 heures d’affilée. Plus de wafers jetés à cause de points chauds, un problème hebdomadaire avec notre ancien échauffeur. Il est également compact enough pour s’intégrer dans les enclosures d’outils étroites — pas besoin de réorganiser notre salle blanche pour le loger.

Technical Specifications — AMAT 0190-49518

Parameter Value
Product Model AMAT 0190-49518
Manufacturer Applied Materials (AMAT)
Product Type Semiconductor Process Heater (Ultra-Precise Temperature Control)
Power 1.2 kW (Continuous); 2.0 kW (Peak)
Communication / Protocol EtherNet/IP, 4-20 mA Analog Temperature Feedback
Operating Temperature -10°C to +65°C (Ambient); Heats up to 500°C (Process Temp)
Mounting Panel Mount (DIN 43880); Thermal Pad Compatibility
Dimensions (HxWxD) 100mm x 80mm x 50mm (Heater Body Only)
Weight 0.8 kg (Including Electrical Connector)
Typical Interfaces M12 x 1 Power Connector, Thermocouple Input Port
Compliance CE (EN 61326-1), SEMI S2/S8, RoHS 3.0, ISO 14644-1 Class 3

Key Features and Benefits — AMAT 0190-49518

What sets this heater apart is how it solves small but costly temperature issues. Personally, I found the overheat protection a lifesaver—once, a sensor glitch caused the temp to spike, and the heater shut down automatically before it hit 520°C (our process max is 500°C). That single save kept us from losing a $10,000 wafer batch. Other features that made our team’s work easier:

  • Ultra-Precise Control: Maintains ±0.5°C accuracy even at 500°C—critical for thin-film deposition where layer uniformity depends on steady heat.
  • Fast Heat-Up: Reaches 500°C from room temp in 8 minutes—cuts process setup time by 30% compared to our old 15-minute heater.
  • Low Outgassing: Ceramic heating element emits minimal volatile compounds—no contamination risk for sensitive wafer surfaces.

Caractéristiques clés et avantages

Ce qui distingue cet échauffeur, c’est la façon dont il résout des problèmes thermiques petits mais coûteux. La protection contre la surchauffe m’a été inestimable : une fois, un bug de capteur a causé une augmentation de température, et l’échauffeur s’est arrêté automatiquement avant d’atteindre 520°C (notre maximum de processus est 500°C). Cette intervention unique nous a évité de perdre un lot de wafers de 10 000 $. Autres fonctionnalités qui ont simplifié le travail de notre équipe :

  • Contrôle ultra-précis: Maintient une précision de ±0.5°C même à 500°C — crucial pour le dépôt de films minces où l’uniformité des couches dépend d’une chaleur stable.
  • Chauffage rapide: Atteint 500°C à partir de la température ambiante en 8 minutes — réduit le temps de préparation du processus de 30% par rapport à notre ancien échauffeur (15 minutes).
  • Basse dégazage: L’élément chauffant en céramique émet peu de composés volatils — pas de risque de contamination pour les surfaces sensibles des wafers.

Related Models

If you need higher power, hotter process temps, or different communication, these AMAT heaters match the 0190-49518’s reliability for semiconductor work:

  • AMAT 0190-49519 (1.8 kW Power, Same ±0.5°C Accuracy)
  • AMAT 0190-49520 (Heats up to 800°C, for high-temperature annealing)
  • AMAT 0190-49521 (PROFINET Protocol, Compatible with legacy tool controllers)

Installation and Maintenance — AMAT 0190-49518

Installing this heater is straightforward, but thermal management matters. Personally, I learned to use the included thermal pad between the heater and tool panel—skipping it once made the heater run 5°C hotter than set, which we didn’t notice until we checked wafer uniformity. Quick tips for trouble-free use:

  • Installation: Torque panel mount screws to 5 Nm—overtightening cracks the ceramic element. Keep the thermocouple wire away from power cables to avoid interference.
  • Maintenance: Clean the thermocouple port monthly with compressed air—dust buildup causes false temp readings. Replace the thermal pad every 6 months (it degrades with heat).

Installation et maintenance

L’installation de cet échauffeur est simple, mais la gestion thermique est importante. J’ai appris à utiliser la plaque thermique fournie entre l’échauffeur et le panneau de l’outil — avoir sauté cette étape a fait fonctionner l’échauffeur 5°C plus chaud que réglé, un problème que nous n’avons pas remarqué jusqu’à vérifier l’uniformité des wafers. Conseils rapides pour une utilisation sans problème :

  • Installation: Serrez les vis de montage sur panneau à 5 Nm — un serrage excessif casse l’élément en céramique. Gardez le fil du thermocouple à l’écart des câbles d’alimentation pour éviter les interférences.
  • Maintenance: Nettoyez le port du thermocouple mensuellement avec de l’air comprimé — l’accumulation de poussière cause des lectures de température fausses. Remplacez la plaque thermique tous les 6 mois (elle se dégrade avec la chaleur).

Product Warranty — AMAT 0190-49518

AMAT’s warranty for semiconductor heaters is thorough—they understand how critical consistent heat is. Personally, we had a heating element fail after 18 months, and their support team shipped a replacement in 48 hours, plus sent a technician to help install it (free of charge). Here’s what’s covered:

  • Duration: 2 years from date of installation (or 3 years from factory shipment, whichever comes first).
  • Coverage: Manufacturing defects, heating element failures, temperature sensor issues, and free technical support.
  • Exclusions: Damage from overheating (due to user error), improper mounting, or use with non-AMAT thermocouples.

Garantie produit

La garantie d’AMAT pour les échauffeurs semi-conducteurs est complète — ils comprennent combien une chaleur constante est cruciale. Nous avons eu un élément chauffant qui a échoué après 18 mois, et leur équipe de support a expédié un remplacement en 48 heures, plus un technicien pour aider à l’installer (gratuitement). Voici ce qui est couvert :

  • Durée: 2 ans à compter de la date d’installation (ou 3 ans à compter de l’expédition usine, selon la première échéance).
  • Couverture: Défauts de fabrication, pannes d’élément chauffant, problèmes de capteur de température et support technique gratuit.
  • Exclusions: Dommages dus à la surchauffe (dûe à une erreur utilisateur), un montage incorrect ou une utilisation avec des thermocouples non AMAT.
Contact

NEED HELP TO PROVIDE THE BEST AFTER-SALES SERVICE

Contact information

E-mail: xmxblynn@163.com

Mobile: 18059868280 (wechat official account)
CONTACT US