I’ve worked with GE’s protective relays in power generation plants for years, and the 339-E-P5-G5-H-E-S-N-N-SN-D-N stands out for how it balances complexity and usability. Personally, I found that its ability to monitor both overcurrent and voltage fluctuations—all in one unit—cuts down on the number of modules we need in the control cabinet. It’s designed for medium-voltage switchgear, so it’s built tough: I had one installed in a rooftop substation that sees freezing winters and scorching summers, and it never missed a trip signal in 14 months. What I really appreciate is that it doesn’t require a PhD to configure; the basic settings can be done with a few button presses, which saves time when you’re rushing to fix a grid issue.
J’ai travaillé avec des relais de protection GE dans des centrales de production d’énergie pendant des années, et le 339-E-P5-G5-H-E-S-N-N-SN-D-N se distingue par son équilibre entre complexité et facilité d’utilisation. Personnellement, j’ai remarqué que sa capacité à surveiller à la fois les surintensités et les fluctuations de tension — toutes dans un seul appareil — réduit le nombre de modules nécessaires dans l’armoire de contrôle. Il est conçu pour les appareillages à moyenne tension, donc il est robuste : j’en ai un installé dans une sous-station au toit qui connaît des hivers froids et des étés chauds, et il n’a jamais manqué un signal de déclenchement en 14 mois. Ce que j’apprécie vraiment, c’est qu’il ne faut pas être un expert pour le configurer ; les paramètres de base peuvent être ajustés avec quelques presses de bouton, ce qui gagne du temps quand on doit rapidement réparer un problème de réseau.
| Parameter | Value |
|---|---|
| Product Model | GE 339-E-P5-G5-H-E-S-N-N-SN-D-N |
| Manufacturer | GE (General Electric) |
| Product Type | Medium-Voltage Protective Relay Module |
| Power | Input: 24V DC ±15% / 125V DC ±15%; Power Consumption: 15W max |
| Communication / Protocol | Modbus RTU (RS-485); GE SRTP (Serial Real-Time Protocol) |
| Operating Temperature | -30°C to 70°C (-22°F to 158°F); Humidity: 5-95% RH (non-condensing) |
| Mounting | Panel Mount (DIN 43700); Depth: 180mm max |
| Dimensions (HxWxD) | 140mm x 100mm x 180mm |
| Weight | 850g (1.87 lbs) |
| Typical Interfaces | 8x digital inputs; 4x relay outputs; 1x RS-485 port; 1x LCD display; 6x status LEDs |
| Compliance | CE (EN 61850-3); UL 508; IEC 60255-1 (Relay Standards) |
One of the biggest wins with this relay is its built-in fault logging—personally, I found that it saves hours of troubleshooting. Last month, a feeder tripped unexpectedly, and the relay had stored the exact current and voltage values at the time of the fault, so we didn’t have to guess what happened. Another plus is the dual power input; if one DC source fails, it switches to the other automatically—critical for power plants where downtime isn’t an option. The LCD display is also a nice touch; it’s backlit, so you can read it even in dimly lit control rooms, unlike some older GE relays that require a flashlight. And since it’s IEC 60255-certified, you know it meets global safety standards—no need to worry about compatibility when installing it in international sites.
Un des plus grands avantages de ce relais est sa journalisation de défauts intégrée — personnellement, j’ai trouvé qu’elle économise des heures de dépannage. Le mois dernier, un alimenteur a déclenché inattendument, et le relais avait stocké les valeurs exactes de courant et de tension au moment du défaut, donc nous n’avions pas à deviner ce qui s’est passé. Un autre point positif est l’alimentation double ; si une source DC échoue, il passe automatiquement à l’autre — crucial pour les centrales de production d’énergie où l’arrêt n’est pas possible. L’affichage LCD est également un plus ; il est rétroéclairé, donc on peut le lire même dans les salles de contrôle peu éclairées, contrairement à certains relais GE plus anciens qui nécessitent une lampe de poche. Et comme il est certifié IEC 60255, vous savez qu’il répond aux normes de sécurité mondiales — pas besoin de vous soucier de la compatibilité lors de son installation dans des sites internationaux.
If the 339-E-P5-G5-H-E-S-N-N-SN-D-N doesn’t fit your voltage needs, GE has solid alternatives. The 339-E-P5-G5-H-E-S-N-N-SN-D-P is rated for high-voltage (up to 35kV) systems, while the 339-E-P5-G5-H-E-S-N-N-SN-C-N adds Ethernet (IEC 61850) for smart grid integration. For applications needing more outputs, the 339-E-P5-G5-H-E-S-N-N-SN-D-Q has 8 relay outputs instead of 4. And for extreme temperatures (like arctic sites), the 339-E-P5-G5-H-E-S-N-N-SN-D-R works down to -40°C. All these share the same core protection features, so training your team on one means they can handle the rest. For a detailed spec comparison, check https://gk-dcs.com/.
Installing this relay is straightforward, but my tip is to double-check the wiring diagram—its 8 digital inputs look similar, and mixing up a current transformer wire with a voltage input can damage the unit (I learned that the hard way once). The panel mount holes line up with standard GE switchgear, so you don’t need to drill new ones. Maintenance is minimal: wipe the LCD screen with a soft cloth every month to remove dust, and test the relay outputs once a quarter using the built-in test mode. I also like that GE included a reset button on the front—no need to open the cabinet to clear a fault, which saves time during emergencies. Even if you’re new to GE protective relays, you’ll have this set up in under an hour.
L’installation de ce relais est simple, mais mon conseil est de vérifier deux fois le schéma de câblage — ses 8 entrées numériques sont semblables, et confondre un fil de transformateur de courant avec une entrée de tension peut endommager l’appareil (j’ai appris ça à mes dépens une fois). Les trous de montage sur panneau s’alignent avec les appareillages GE standards, donc pas besoin de percer de nouveaux trous. La maintenance est minimale : essuyez l’écran LCD avec un chiffon doux chaque mois pour éliminer la poussière, et testez les sorties de relais une fois par trimestre à l’aide du mode test intégré. J’aime aussi qu’GE ait inclus un bouton de réinitialisation à l’avant — pas besoin d’ouvrir l’armoire pour effacer un défaut, ce qui gagne du temps en cas d’urgence. Même si vous découvrez les relais de protection GE, vous l’aurez configuré en moins d’une heure.
GE’s warranty for this relay is solid—2 years from purchase, covering all manufacturing defects. I once had a unit where the RS-485 port stopped communicating after 20 months, and GE sent a replacement in 5 days, no complicated claims process. You can extend the warranty to 3 years by registering the relay on GE’s Industrial portal within 30 days of installation—definitely worth it for gear that protects critical power infrastructure. Just note: It doesn’t cover damage from improper wiring or physical impact (like dropping tools on it during maintenance), but that’s standard for industrial relays. What I appreciate most is GE’s technical support—when I called with a question about fault logging, the rep walked me through the steps in 2 minutes, no jargon.
La garantie d’GE pour ce relais est solide — 2 ans à compter de l’achat, couvrant tous les défauts de fabrication. J’ai eu un appareil où le port RS-485 a cessé de communiquer après 20 mois, et GE a envoyé un remplacement en 5 jours, sans processus de réclamation compliqué. Vous pouvez étendre la garantie à 3 ans en enregistrant le relais sur le portail Industrial d’GE dans les 30 jours suivant l’installation — c’est définitivement utile pour un équipement qui protège une infrastructure électrique critique. Notez simplement : Elle ne couvre pas les dommages dus à un câblage incorrect ou à un impact physique (comme laisser tomber des outils sur lui pendant la maintenance), mais c’est la norme pour les relais industriels. Ce que j’apprécie le plus, c’est le support technique d’GE — quand j’ai appelé avec une question sur la journalisation de défauts, le conseiller me l’a expliqué en 2 minutes, sans jargon.